As solar installations become larger, system designers are increasingly working with higher DC voltages to move power efficiently across photovoltaic infrastructure. But higher voltage also makes circuit protection more demanding. A fuse used in a 1500 VDC solar system must be designed to safely interrupt DC faults—not simply carry the required operating current.
ADLER addresses this requirement with its A94 and A95 series gPV photovoltaic fuses, designed for high-voltage PV protection. Both families offer options rated for 1500 VDC and are intended for applications including PV combiner and junction boxes, inverters, and battery charge controllers. They are designed to photovoltaic fuse standards including UL 248-19 and IEC 60269-6.
For procurement teams and engineers building or maintaining solar power systems, these products provide several current-rating options while keeping the focus on one important requirement: selecting protection specifically engineered for photovoltaic DC circuits.
Why gPV Fuses Matter in Solar Systems

A photovoltaic array can contain many strings operating together on a common DC system. Under normal conditions, those strings feed power toward the inverter. If an electrical fault occurs, however, current from other parallel strings or connected equipment can flow back toward the affected circuit.
A properly selected gPV fuse helps interrupt that overcurrent and isolate the faulted circuit, reducing the risk of damage to PV wiring and connected equipment. This makes fuse selection particularly important in combiner boxes, inverter DC inputs, and other locations where multiple PV circuits come together.
The challenge is that DC faults are different from ordinary AC faults. There is no natural current zero-crossing to help extinguish an arc, so the fuse must be specifically designed and rated for the DC voltage and expected fault conditions. ADLER's A94 and A95 families are designed around these photovoltaic requirements rather than being general-purpose fuses adapted to solar use.
ADLER Products for Photovoltaic Protection
The A94 series uses a compact 22 × 58 mm cylindrical format. ADLER's current datasheet covers ratings from 1 A to 80 A; products from 1 A through 65 A are listed with a 30 kA breaking capacity at 1500 VDC.
The A95 series uses a larger 24 × 65 mm format. Its current datasheet covers 20 A through 100 A and lists a 30 kA rated breaking capacity at 1500 VDC. ADLER also identifies BH500 and BH501 as DIN-rail holder options for the A95 cylindrical format.
Here are several ADLER options relevant to high-voltage PV designs:
ADLER Product | Voltage | Current | Example Application |
A942200B00 | 1500 VDC | 20 A | PV string or combiner-box circuit requiring 20 A protection |
A942300B00 | 1500 VDC | 30 A | PV combiner or inverter DC circuit requiring 30 A protection |
A942400B00 | 1500 VDC | 40 A | Higher-current PV combiner or DC power-conversion circuit |
A942500B00 | 1500 VDC | 50 A | PV circuit protection where a 50 A gPV fuse is specified |
A942600B00 | 1500 VDC | 60 A | Higher-current PV protection using the 22 × 58 mm A94 format |
A952350B00 | 1500 VDC | 35 A | PV combiner, inverter, or charge-controller circuit |
A952550B00 | 1500 VDC | 55 A | Higher-current PV protection using the 24 × 65 mm A95 format |
A952650B00 | 1500 VDC | 65 A | 65 A photovoltaic protection in the A95 platform |
The listed A94 products are covered by ADLER's current 30 kA-at-1500-VDC datasheet range, while the three selected A95 parts are also specified at 30 kA and carry UL and TÜV certification markings in the current datasheet.
The current rating should not be selected from this table alone. It must match the actual PV system design and protection requirements.
Choosing the Right Protection Is More Than Choosing an Amp Rating
Two fuses can have the same current rating and still behave differently during a fault. Engineers also need to consider system voltage, prospective fault current, fuse time-current characteristics, installation temperature, circuit configuration, and coordination with cables and connected equipment.
The fuse holder matters as well.
ADLER's BH400 is a DIN-rail, touch-safe holder designed for 22 × 58 mm cylindrical PV fuses, including the A94 format. Its current datasheet specifies 1500 VDC, up to 80 A, a 10 kA rated breaking capacity, and a maximum fuse dissipation of 8 W. It is designed to UL 4248-19 and EN 60947-3.
This is an important reminder for both engineers and purchasing teams: physical compatibility does not automatically mean electrical or thermal compatibility. The fuse and holder should be evaluated together for the actual operating current, fault level, temperature, and installation conditions.
For A95 cylindrical fuses, ADLER specifies its BH500/BH501 holder family, rather than BH400.
Where ADLER A94 and A95 Fuses Can Be Used
Based on ADLER's current documentation, the strongest applications for the A94 and A95 series include:
- PV combiner and junction boxes, where multiple solar strings are brought together and individual circuits may require overcurrent protection.
- Solar inverter DC circuits, helping provide protection on the photovoltaic side of the power-conversion system.
- PV string protection, where the selected fuse rating and system design require gPV overcurrent protection.
- Battery charge-controller circuits associated with photovoltaic systems, an application specifically identified by ADLER for both families.
These products should not be treated as universal fuses for every 1500 VDC application. A product carrying the correct voltage rating still needs to match the expected current, fault conditions, holder, thermal environment, and applicable system requirements.
Building Reliable Protection into High-Voltage Solar Systems
As photovoltaic systems move more power at higher DC voltages, the protection components around the inverter, strings, and combiner box become increasingly important.
ADLER's A94 and A95 gPV fuse families provide 1500 VDC photovoltaic protection across multiple current ratings and package formats, giving designers and procurement teams options for PV combiner boxes, inverter DC circuits, and related solar power-conversion equipment. Their PV-specific design and documented breaking capability make them more appropriate to evaluate for these applications than a general-purpose fuse selected on voltage and amperage alone.
Need help identifying the right ADLER fuse for your application?
Contact IBS Electronics with your part number, requirements, or BOM.
Why We Are One
For over 40 years, IBS Electronics Group has provided a broad range of integrated supply chain and electronicsmanufacturing solutions tailored specific to our customer's operations. As your one source for the industry’s top brands all in one place, our engineers specialize in reducing supply chain complexity and are here to provide you with dedicated support from prototype to production.